Vital Signs Patient Monitor With NIBP & SpO2 Patient Monitor Portable

Vital Signs Patient Monitor with NIBP & SpO2 patient monitor portable,Four parameters of NIBP,SpO2,Pulse Rate,Temperature.

Chat Now
Product details

BLV-III Vital Signs Patient Monitor/ NIBP/SpO2 patient monitor

Vital Signs Patient Monitor is a tabletop model and easy to carry.

The size of main unit is 280(W)*190(H)*100(D)mm; N.W. is 1kg;

The packing size for single model is 33*32*15cm with standard export cartons.

This model can be applied in the hospital’s operation room, ICU, clinic section office, Out-patient department, sickroom and emergency treatment.

 

Features

Four parameters: NIBP,SpO2,Pulse Rate,Temperature.

SpO2 waveform, PR strength display.

2.8 inch color LCD with real time display.

Storage/Review trend data up to 3888 groups, data save time interval settable.

Audio and visual alarm when parameters exceeded and sensor-off.

Built-in rechargeable Li-ion battery, up to 5 hour running time.

Automatic shutdown for power saving in 10 mins

 

Specifications

1. NIBP

Patient: Adult and Pediatric

Measurement method: Oscillometric

Range:Adult:30mmHg~255mmHg  Pediatric: 30mmHg~160mmHg

Measurement unite: mmHg/kPa selectable

Measurement mode: Manual, Auto, STAT

Measurement Type: SYS, DIA, MAP

Measurement interval in AUTO mode:1,2,3,5,10,15,20,30,45,60Min

Measuring period in STAT mode: 5 Min

Resolution:1mmHg

Over-pressure protection

2. SpO2

Patient: Adult, child

Range: 0~100%

Resolution: 1 %

Accuracy: ±2 %(90~99%), ±3 %(70~89%),unspecified (<70%)

3. TEMP

Channel: 1

Input: Body surface thermal-sensitive resistor temperature sensor

Measurement Unit: /F selectable

Range: 0~50

Resolution: 0.1

Accuracy: ±0.2

 

4. Pulse Rate

Range: 30~250bpm

Resolution: 1bpm

Accuracy: ±1bpm

 

5. Alarm

Sensors off alarm and alarm limit exceeded alarm

Mode: The parameter’s measurement flashes on the screen, the speaker sounds the alarm and LED flashes on the monitor

Setup: User-adjustable high and Low limits

6. Storage and Review

Trend data up to 3888 groups.

 

7. Display Mode

Type:240*320 dot matrix color TFT LCD screen and LED screen

LCD Display area:44mm*59mm

LED Display area: 167mm*79mm

 

8. Power Requirements

AC power adapter

Input: AC 100~240V, 50/60Hz, 0.7A

Output: DC 5V,2.5A

Internal battery             

Type: 2800mAh/3.7V built-in Li-ion rechargeable battery

Operating Time: 5 hours of stand-by time with a full battery.

Recharge time: 8hours

 

Accessories

Main unit                             1pc

NIBP extension tube                   1pc

Adult NIBP cuff                        1pc

Adult SPO2 Sensor                    1pc

Surface temprature probe               1pc

AC power adaptor                      1pc

USB Cable                            1pc

The operator’s manual                  1pc


Related Products
Feedback

Our Service

Hereby,we are committed to offer new free samples and 1 Year warranty for all of our hearing aid & medical device. Providing good quality and better service to all customers is the BYVision's Mission. Quality is the life of enterprise and Service is the blood of enterprise as the Philosophy. Bettery hearing and better life!

Feedback

Contact Us

Address:4-6 floor, Keji Dasha, Xingwei Industry Zone, Xinghua Road, Bao’an District, Shenzhen, Guangdong Province, China

Tel: +86-755-23571166

Fax: +86-755-33188679

E-mail: info@byvisiontech.com

CopyRight© Byvision Science Technology Limited